Description
UNIQUE VACUUM SOLUTOINS, manufactures fully / semi auto machines to test and precisely measure the helium leakage through Control valves.
Our machines are configured with below specifications:
Test method |
Evacuation, sniffer |
Valves cycling prior to test |
Automatic, cycles settable through control panel. |
Maximum helium test pressure |
Upto 30 bar |
Ultimate vacuum under evacuation method |
0.001 mbar |
Minimum detectable leak rate |
1X10-8m bar ltrs/sec. |
Auto calibration of helium leak detector |
Built-in |
System calibration to establish the machine factor |
Built in |
Cycle verification process |
Built in |
Recipe creation |
Up to 100 receipes |
Maximum nitrogen test pressure |
Up to 35 bar |
Auto recovery of helium |
optional |
Data logging |
Built in |
Vacuum pumping system configuration |
Rotary vane + booster pumping system |
Fugitive emission test Thermal cycling |
Yes, up to 200 Deg C |
Valve body temperature measurement |
From -197 to +200 Deg C |